The low-cost MTX Series transmitters convert thermocouple or
RTD signals into a 4-20 mA dc signal output that is directly referenced
to the mV input. The MTX transmitters mount directly within any of
NEWPORT’s standard protection heads for connection to your
sensor.
SPECIFICATIONS
Output
Range: 4-20 mA dc
Zero and Span Adjustment Range: ±25% for °F and ±10% for °C Accuracy: ±0.1% of span Operating Temperature Range: -40 to 85°C (-40 to 185°F) Storage Temperature Range: -46 to 121°C (-50 to 250°F) Supply Voltage: 8-50 Vdc Max Loop Resistance:
Dimensions: 44.5 mm Dia. x 31.75 mm H (1.75" x 1.25")
Weight: 34 g (less than 0.5 oz.) Note: Thermocouple Models output proportional to mV output of thermocouple. Not linearized to temperature. To Order (Specify Model No.) Prices Shown in U.S. Dollars
*Specify
Range Code from chart below. Comes with complete operator’s manual.
Ordering Example: MTX-K07 specifies a Type K transmitter, with 0 to 150°C range, $99. RANGE CODES
*Not
available on “T” range
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Copyright 2003,
NEWPORT Electronics, Inc. All rights reserved.
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||