INF-B
• Universal Inputs: DC Voltage/Current, T/C, RTD, Strain
• Accuracy: ±0.005% rdg
• 6-Digit Color Changing LED Display
• Extended 5-Year Warranty at No Extra Charge
• Up to 166 Readings Per Second
• 10 Point Linearization
• 4 Isolated Open Collector Output
• Isolated Analog Output Optional
• Four Relays Optional
• Optional Ethernet or RS-232/RS-485
• RS-232, RS-422, and RS-485 MODBUS Selectable from Menu |
|
 |
i8 Series
• Universal Inputs: Thermocouple, RTD, Process Voltage/Current
• User Friendly, Simple to Configure
• High Quality
• Extended 5-Year Warranty at No Extra Charge
• Powerful Features
• Free Software, ActiveX Controls
• Full Autotune PID Control, Optional
• Totally Programmable Color Displays, Standard
• Temperature Stability: ±0.04°C/°C RTD and ±0.05°C/°C TC @ 25°C , 50ppm / °C process
• Optional Embedded Ethernet
• Both RS-232 and RS-485 MODBUS on One Instrument Selectable from Menu, Optional
• Built-in Excitation, Standard
• 2 Control or Alarm Outputs, Choice of dc Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current, Optional |
|

Dual Horizontal

Dual Vertical |
i8DH / i8DV Series
• Universal Inputs: Thermocouple, RTD, Process Voltage/Current
• User Friendly, Simple to Configure
• High Quality
• Extended 5-Year Warranty at No Extra Charge
• Powerful Features
• Free Software, ActiveX Controls
• Full Autotune PID Control, Optional
• Totally Programmable Color Displays, Standard
• Temperature Stability: ±0.04°C/°C RTD and ±0.05°C/°C TC @ 25°C , 50ppm / °C process
• Optional Embedded Ethernet
• Both RS-232 and RS-485 MODBUS on One Instrument Selectable from Menu, Optional
• Built-in Excitation, Standard
• 2 Control or Alarm Outputs, Choice of dc Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current, Optional |
|

Ultra Compact Case |
i8C Series
• Universal Inputs: Thermocouple, RTD, Process Voltage/Current
• User Friendly, Simple to Configure
• High Quality
• Extended 5-Year Warranty at No Extra Charge
• Powerful Features
• Free Software, ActiveX Controls
• Full Autotune PID Control, Optional
• Totally Programmable Color Displays, Standard
• Temperature Stability: ±0.04°C/°C RTD and ±0.05°C/°C TC @ 25°C , 50ppm / °C process
• Both RS-232 and RS-485 MODBUS on One Instrument Selectable from Menu, Optional
• Built-in Excitation, Standard
• 2 Control or Alarm Outputs, Choice of dc Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current, Optional |
|

Single Display

Dual Display |
i16 Series
• Universal Inputs: Thermocouple, RTD, Process Voltage/Current
• User Friendly, Simple to Configure
• High Quality
• Extended 5-Year Warranty at No Extra Charge
• Powerful Features
• Free Software, ActiveX Controls
• Full Autotune PID Control, Optional
• Totally Programmable Color Displays, Standard
• Temperature Stability: ±0.04°C/°C RTD and ±0.05°C/°C TC @ 25°C , 50ppm / °C process
• Optional Embedded Ethernet
• Both RS-232 and RS-485 MODBUS on One Instrument Selectable from Menu, Optional
• Built-in Excitation, Standard
• 2 Control or Alarm Outputs, Choice of dc Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current, Optional |
|
|
i32 Series
• Universal Inputs: Thermocouple, RTD, Process Voltage/Current
• User Friendly, Simple to Configure
• High Quality
• Extended 5-Year Warranty at No Extra Charge
• Powerful Features
• Free Software, ActiveX Controls
• Full Autotune PID Control, Optional
• Totally Programmable Color Displays, Standard
• Temperature Stability: ±0.04°C/°C RTD and ±0.05°C/°C TC @ 25°C , 50ppm / °C process
• Both RS-232 and RS-485 MODBUS on One Instrument Selectable from Menu, Optional
• Built-in Excitation, Standard
• 2 Control or Alarm Outputs, Choice of dc Pulse, Solid State Relays, Mechanical Relays, Analog Voltage and Current, Optional |
|

1/8 DIN Horizontal & Vertical,
1/16 DIN and 1/32 DIN Sizes
|
iTH Series
• Dual Loop Control
• Humidity + Temperature
• High Accuracy ±0.5°C and ±2% RH
• 4 Popular DIN Sizes
• Ethernet and Serial Communications (optional)
• User-friendly, Simple to Configure
• Full Autotune PID Control
• 2 Control or Alarm Outputs (optional)
• Choice of Relays, SSR, DC Pulse, Analog Voltage and Current
• Programmable Ramp and Soak for Humidity and/or Temperature
• NEMA-4, IP65 Front Bezel |
iSERVER MicroServer |
| TEMPERATURE + HUMIDITY with Flash Memory iServer MicroServer |
$395 |
 |
iTHX-M
• Temperature + Humidity
• Virtual Chart Recorder
• Flash Memory
• LCD Display
• Two Alarm Relays
• Battery Back-up
• Web Server
• Accurate Readings
• Password Protection
• Email Alarms
• Data Logging
• SENSOR SPECS:
Relative Humidity (RH) Accuracy/Range: ±2% for 10 to 90%
±3% for 0 to 10% and 90 to 100%
Resolution: 0.03%
Temperature (T) Range: 0°C to 70°C (32°F to 158°F)
Accuracy: ±0.5°C @ 25°C
Resolution: 0.01°C |
| TEMPERATURE + HUMIDITY iServer MicroServer |
$295 |
 |
iTHX-W
• Temperature + Humidity
• Dew Point
• Web Server
• Accurate Readings
• Password Protection
• Email Alarms
• Data Logging
• Virtual Chart Recorder
• SENSOR SPECS:
Relative Humidity (RH) Accuracy/Range: ±2% for 10 to 90%
±3% for 0 to 10% and 90 to 100%
Resolution: 0.03%
Temperature (T) Range: 0°C to 70°C (32°F to 158°F)
Accuracy: ±0.5°C @ 25°C
Resolution: 0.01°C |
| INDUSTRIAL TEMPERATURE + HUMIDITY iServer MicroServer |
$295 |
 |
iTHX-2
• Temperature + Humidity
• Dew Point
• Web Server
• Accurate Readings
• Password Protection
• Email Alarms
• Data Logging
• Virtual Chart Recorder
• SENSOR SPECS:
Relative Humidity (RH): Accuracy/Range: ±2% for 10 to 90%
±3% for 0 to 10% and 90 to 100% Resolution: 0.03%
Temperature (T): Accuracy/Range @ 25°C:
±0.5°C for 0 to 80°C (±1°F for 32 to 176°F)
±1°C for -40 to 0 and 80 to 124°C (±2°F for -40 to 32 and 176 to 254°F) Resolution: 0.01°C |
BIG DISPLAYS |
|
|
iLD24-UTP, iLD44-UTP
• Input: Thermocouple/RTD 4-20 mA/Analog Voltage/Analog Current
• Display: 4-Digit, 7-Segment 2 1/4-inch or 4 inch high digits, Red, Green, & Amber LED
• Optional Embedded Ethernet
• Accuracy: ±0.5%C; 0.03% reading process
• Mechanical: 2.25" (57.2 mm), 4-Digit:
11.75" L x 5.375" W x 2.875" D (289 mm L x 137 mm W x 73 mmD)
• Mechanical: 4.00" (101.6 mm), 4-Digit:
18.11" L x 8.31" W x 3.76" D (480 mm L x 211 mm W x 95 mm D) |
|
 |
INFT
NEW INFO® Service Document: 103
• Input: Thermocouples: J, K, T, E, R, S, B, N, J–DIN; RTD: 6 ohms to 6 kohms a = 0.00385, 0.00392 or linear
• Display: 6-Digit, 14-Segment Red or Green LED Alphanumeric
• Accuracy: Thermocouples: ±0.2°C ±1/2 lsd; RTD: Pt100 ±0.2°C ±1/2 lsd 10 ohm Cu ±1°C
• Communications Options: Isolated RS-232, RS-485/RS-422, BCD
• Additional Features: User Programmable, Min/Max Recall, Digital Filtering |
|

NEW!
Isolated Analog Output |
INFCT-B
• Input: Thermocouples: J, K, T, J-DIN
• Display: 4-digit, LED 9-segment, 21 mm (0.83") (Displays - Red, Green, & Amber)
• Accuracy: ±0.5°C @ 25°C Thermocouple: ±0.05°C/°C
• Optional Features: On/Off or Proportional Control |
|

NEW!
Isolated Analog Output |
INFCTP
NEW INFO® Service Document: 203
• Input: Thermocouples: J, K, T, J-DIN
• Display: 4-Digit, 14-Segment Red or Green LED
• Accuracy: ±0.5°C @ 25°C Thermocouple: ±0.05°C/°C
• Optional Features: On/Off or Proportional Control |
|

NEW!
Isolated Analog Output |
INFCR-B
• Input: RTD: 2, 3 or 4-wire, 100 ohm, a = 0.00385
• Display: 4-digit, LED 9-segment, 21 mm (0.83") (Displays - Red, Green, & Amber)
• Accuracy: ±0.5°C @ 25°C RTD: ±0.04°C/°C
• Optional Features: On/Off or Proportional Control |
|

NEW!
Isolated Analog Output |
INFCRP
NEW INFO® Service Document: 203
• Input: RTD: 2, 3 or 4-wire, 100 ohm, a = 0.00385
• Display: 4-Digit, 14-Segment Red or Green LED
• Accuracy: ±0.5°C @ 25°C RTD: ±0.04°C/°C
• Optional Features: On/Off or Proportional Control |
|
 |
INFCH
NEW INFO® Service Document: 206
• Input: Thermistors: 400 Series 2252 ohm; 700 series 3-wire
• Display: 4-Digit, 14-Segment Red or Green LED
• Accuracy: ±0.1°C
• Optional Features: On/Off or Proportional Control |
|
NEW!
Isolated Analog Output |
INFCDT / INFCDR
High Performance INFINITY® Series Meters
NEW INFO® Service Document: 205
• Input: Thermocouples: J, K, T, J-DIN; RTD: 2, 3, or 4-wire, 100 ohm, a = 0.00385, INFCDR also 0.00392; INFCDR differential input, T1, T2 or T1-T2 displayed
• Display: 4-Digit, 14-Segment Red or Green LED
• Accuracy: ±0.5°C @ 25°C, ±0.04°C/°C 25°C
• Optional Features: On/Off or Proportional Control |
|
|
IDT
NEW INFO® Service Document: 118
• Input: Thermocouples: J, K, T, E, R, S, N, or J-DIN
• Display: 4-Digit, 7-Segment Red or Green LED
• Accuracy: ±0.5°C
• Additional Features: Max and Min Recall, Display Hold, Short 4" (100 mm) 1/8 DIN case |
|
PID CONTROLLER |
ICN77000
NEW INFO® Service Document: 1582
• Input: Thermocouples: J, K, T, E, R, S, B, C, N, and J-DIN; RTD: Pt100, 500, 1000 with 385 or 392 Curve, Process Voltage or Current
• Display: Dual 4-Digit
• Ramp to Setpoint
• Universal Power: 90-250 Vac or Vdc
• Dual Output & Dual Alarm Capability
• Ramp to Setpoint Optional RS232 or RS-485 Communications |
|
Thermocouple
J, K, T, E, R, S, B, N, J-DIN |
| iDRN-TC - Analog Output |
$325 |
| iDRX-TC - RS-485 Output |
$250 |
|
• 1800 Volts 3-Way Isolation
• Input Overvoltage Protection
• 13-Bit Resolution
• 10 Vdc Excitation
• Software Selectable Scaling and Digital Filtering
• 0.2% Accuracy
• Output: 0 to 10 Vdc @ 10 mA max, 0 to 20 mA or 4 to 20 mA, 500 ohm max. loop resistance; 10 Vdc compliance
• Input Ranges: 30 mV or 100 mV full scale spans |
|
RTD INPUT
385 or 392 alpha
100, 500, 1000 ohm |
| iDRN-RTD - Analog Output |
$355 |
| iDRX-RTD - RS-485 Output |
$250 |
|
• 1800 Volts 3-Way Isolation
• Input Overvoltage Protection
• 0.1°C Resolution
• 3 Readings/Sec
• Software Selectable Scaling and Digital Filtering
• Temperature Stability 0.05°C/°C
• Output: 0 to 10 Vdc @ 10 mA max, 0 to 20 mA or 4 to 20 mA, 500 ohm max. loop resistance; 10 Vdc compliance
• Input Accuracy: ±0.5°C for Platinum RTD’s |
|
|

SUPER MCJ
Thermocouple to Analog Connector/Converter |
|
|

205/305
Compact Temperature Panel Meter |
|
|
INFBT
High-Performance INFINITY® Series, Single & Ten Channel Models
• Input: Thermocouples: J, K, T, E, R, S, B, N, J–DIN; RTD: 6 ohms to 6 kohms a = 0.00385, 0.00392 or linear
• Display: 6-Digit, 14-Segment Red or Green LED Alphanumeric
• Accuracy: Thermocouples: ±0.2°C ±1/2 lsd; RTD: Pt100 ±0.2°C ±1/2 lsd 10 ohm Cu ±1°C
• Communications Options: Isolated RS-232, RS-485/RS-422, BCD
• Additional Features: User Programmable, Min/Max Recall, Digital Filtering |
|
|
Q8000 / Q9000
• Input: Thermocouples: J, K, T; Pt100 RTD: a = 0.00385
• Display: 4-Digit, 7-Segment Red or Green LED
• Accuracy: Thermocouples: J ±1.2°C, K ±1.8°C, T ±1.5°C; RTD: ±0.3°C ±0.2%
• Communications Option: BCD Buffered
• Additional Features: Field Configurable, °C/°F |
|
|
Q2000 / Q3000
• Input: Thermocouples: J, K, T; Pt100 RTD: a = 0.00385
• Display: 3 1/2-Digit, 7-Segment Red or Green LED, LCD
• Accuracy: Thermocouples: J ±1.2°C, K ±1.8°C, T ±1.5°C; RTD: ±0.3°C ±0.2%
• Communications Option: BCD Buffered
• Additional Features: Field Configurable, °C/°F |
|

3 1/2 Digit RTD
Meters & Controllers |
Q2000M / Q2000R
• 100 platinum RTD input
• 2,3 or 4-wire connection
• ±1,999-count display span
• 1°C or 1°F resolution (Q2000M)
• 0.1°C or 0.1°F resolution (Q2000R)
• Sensor-break detection
• 120 dB CMR to 500 V |
• 1 mV/count linearized analog output
• LED or LCD display
• Display hold and test
• 120/240 Vac, 5 Vdc, 9-32 Vdc or 26-56 Vdc power
• Screw-terminal barrier strip
• 1/8 DIN case |
|

4-Digit RTD
Meters & Controllers |
Q9000M
• 100 ohm platinum RTD input
• 2,3 or 4-wire connection
• ±9,999-count display span
• 0.1°C or 0.1°F resolution
• Sensor-break detection
• 120 dB CMR to 500 V
• 1 mV/deg linearized analog output |
• LED or LCD display
• Bright, 0.56 in (14.2 mm) LED display
• Display hold and test
• 120/240 Vac, 5 Vdc, 9-32 Vdc or 26-56 Vdc power
• Screw-terminal barrier strip
• 1/8 DIN case |
2002B / 3002 / 169 / 269 / 369 / 469 / 202A (-J, -K, -T, -M, -R) / 2002B-M |
|
|
2002B / 3002
• Input: Thermocouples: J, K, T; RTD: a = 0.00385
• Display: 4 1/2-Digit, 7-Segment Red or Green LED
• Accuracy: Thermocouples: J, K, ±2.5°C or ±0.75%R; T ±0.1°C or ±0.75%R RTD (Pt100): ±0.2%R ±0.1°C @ 0.1°C ±0.1%R ±0.1°C @ 0.01°C
• Additional Features: Short Case |
|
|
202A-J,-K,-T
• J, K or T thermocouple input
• 1° or 0.1° resolution
• °C or °F, jumper-selectable
• 0.05 deg/deg cold-junction error
• Five-segment linearization
• 1 mV/deg linearized recorder output
• 120 dB CMR, 70 dB NMR |
• Bright, 0.56 in (14.2 mm) LED display
• Display hold and test
• 115/230 Vac power
• EMI/RFI filter for AC power
• Screw-terminal barrier strip
• Short (4.1 in deep) 1/8 DIN case |
|
4 1/2 DIGIT (Pt 100)
RTD METER |
2002B-M
• Platinum 100 RTD input
• 1 mA excitation current
• 2-, 3- or 4-wire connection
• 0.1°C or 0.1°F resolution
• °C or °F, jumper-selectable
• Platinum curve linearization
• 120 dB CMR, 70 dB NMR |
• 1 mV/deg linearized analog output
• Bright, 0.56 in (14.2 mm) LED display
• Display hold and test
• 115/230 Vac power
• EMI/RFI filter for AC power
• Screw-terminal barrier strip
• Short (4.1 in deep) 1/8 DIN case |
|

3 1/2 DIGIT (Pt 100)
RTD METER |
202A-M ,-R
• Platinum 100 RTD input
• 1 mA excitation current
• 2-, 3- or 4-wire connection
• 0.1°C or 0.1°F resolution
• °C or °F, jumper-selectable
• Platinum curve linearization
• 120 dB CMR, 70 dB NMR |
• 1 mV/deg linearized analog output
• Bright, 0.56 in (14.2 mm) LED display
• Display hold and test
• 115/230 Vac power
• EMI/RFI filter for AC power
• Screw-terminal barrier strip
• Short (4.1 in deep) 1/8 DIN case |
|
|